<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Archívy Blog - BEZ Transformátory</title>
	<atom:link href="https://www.bez.sk/en/blog/category/blog-en/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.bez.sk/en/blog/category/blog-en/</link>
	<description></description>
	<lastBuildDate>Fri, 10 Apr 2026 12:29:58 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.1</generator>

<image>
	<url>https://www.bez.sk/wp-content/uploads/2024/09/cropped-bez-transformatory-logo-1-32x32.png</url>
	<title>Archívy Blog - BEZ Transformátory</title>
	<link>https://www.bez.sk/en/blog/category/blog-en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Diagnostics and monitoring of transformers: fault prevention</title>
		<link>https://www.bez.sk/en/blog/diagnostics-and-monitoring-of-transformers-fault-prevention/</link>
		
		<dc:creator><![CDATA[Copy Digitalman]]></dc:creator>
		<pubDate>Fri, 16 Jan 2026 10:41:21 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[Types of transformers]]></category>
		<category><![CDATA[dry transformer]]></category>
		<category><![CDATA[oil transformer]]></category>
		<category><![CDATA[special transformers]]></category>
		<category><![CDATA[transformer]]></category>
		<category><![CDATA[transformers for renewable energy]]></category>
		<guid isPermaLink="false">https://www.bez.sk/blog/diagnostics-and-monitoring-of-transformers-fault-prevention/</guid>

					<description><![CDATA[<p>We will answer the questions:Why is transformer monitoring important? What is the difference between oil-immersed and dry-type transformers. We will a...</p>
<p>Článok <a href="https://www.bez.sk/en/blog/diagnostics-and-monitoring-of-transformers-fault-prevention/">Diagnostics and monitoring of transformers: fault prevention</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>In the modern power environment, where more and more emphasis is being placed on efficiency and continuous operation, transformer monitoring is becoming a necessity. Diagnostic systems therefore reflect the specific needs of each type of machine, from conventional oil-immersed to special transformers. </strong></p>

<h2 class="wp-block-heading"><strong>Why is transformer monitoring important?</strong></h2>

<p>In the past, maintenance was carried out reactively, that is, only when a problem arose was it dealt with. However, the present requires <strong>a predictive approach.</strong> However, modern technology allows us to &#8220;see inside&#8221; the machine without having to shut it down. <strong>Real-time monitoring of transformers</strong> can therefore identify up to 90% of incipient faults in their embryonic stage, extending the life of the equipment by decades.  </p>

<h2 class="wp-block-heading"><strong>Tailored diagnostics: from oil to renewables</strong></h2>

<h3 class="wp-block-heading"><strong>Oil Transformers</strong></h3>

<p>For <a href="https://www.bez.sk/en/oil-transformers/" target="_blank" rel="noreferrer noopener">oil-immersed transformers, the key indicator of the condition is</a> the insulating liquid. <strong>The gases dissolved in the oil are analyzed.</strong> The presence of specific gases (hydrogen, methane, acetylene) accurately indicates the type of fault, from electrical discharges to thermal overload.<strong> The water content of the oil is also monitored. </strong>This is critical for maintaining dielectric strength and preventing degradation of the paper insulation.</p>

<figure class="wp-block-image size-full"><img fetchpriority="high" decoding="async" width="2000" height="1334" src="https://www.bez.sk/wp-content/uploads/2026/01/PF__3910.jpg" alt="oil transformers, transformer monitoring, oil transformer manufacturing, transformer warehouse" class="wp-image-11252" srcset="https://www.bez.sk/wp-content/uploads/2026/01/PF__3910.jpg 2000w, https://www.bez.sk/wp-content/uploads/2026/01/PF__3910-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2026/01/PF__3910-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2026/01/PF__3910-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2026/01/PF__3910-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2026/01/PF__3910-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2026/01/PF__3910-705x470.jpg 705w" sizes="(max-width: 2000px) 100vw, 2000px" /></figure>

<p></p>

<h3 class="wp-block-heading"><strong>Dry transformers</strong></h3>

<p><a href="https://www.bez.sk/en/dry-transformers/" target="_blank" rel="noreferrer noopener">Dry transformers,</a> insulated with epoxy resin, are ideal for areas with high fire safety requirements. <strong>Monitoring of thermal points is important.</strong> Using PT100 or fibre optic sensors, the winding temperature is monitored in real time, preventing thermal degradation of the resin. <strong>Partial discharge measurements are also an effective method.</strong> This method detects in time micro-cracks in the insulation that could lead to a fatal short circuit.</p>

<figure class="wp-block-image size-full"><img decoding="async" width="2000" height="1334" src="https://www.bez.sk/wp-content/uploads/2026/01/PF__4031.jpg" alt="dry transformers, transformer monitoring," class="wp-image-11256" srcset="https://www.bez.sk/wp-content/uploads/2026/01/PF__4031.jpg 2000w, https://www.bez.sk/wp-content/uploads/2026/01/PF__4031-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2026/01/PF__4031-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2026/01/PF__4031-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2026/01/PF__4031-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2026/01/PF__4031-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2026/01/PF__4031-705x470.jpg 705w" sizes="(max-width: 2000px) 100vw, 2000px" /></figure>

<p></p>

<h3 class="wp-block-heading"><strong>Special transformers</strong></h3>

<p>In industrial plants, <a href="https://www.bez.sk/en/special-transformers/" target="_blank" rel="noreferrer noopener">transformers face high</a> current surges and harmonic distortion. Therefore <strong>,</strong> we <strong>analyze the mechanical vibration.</strong> We monitor the stability of the core and windings, which are stressed by dynamic forces. We do not neglect the monitoring of tap changers. Monitoring the condition of the contacts directly under load eliminates the risk of mechanical failure.    </p>

<h3 class="wp-block-heading"><strong>Transformers for renewable energy</strong></h3>

<p>Photovoltaic and wind power plants present a <a href="https://www.bez.sk/en/transformers-for-renewable-energy/" target="_blank" rel="noreferrer noopener">new challenge for transformers</a> due to cyclical and unstable loads. Adaptive monitoring is important. Our RES systems take into account frequent temperature fluctuations and variable power output to optimize the operation of substations in smart grids.  </p>

<h2 class="wp-block-heading"><strong>Benefits of systematic monitoring of transformers for operation</strong></h2>

<p>The introduction of modern diagnostic methods is not just about technical measurements, but about strategic asset management. The correct interpretation of data brings many benefits to operators: </p>

<ul class="wp-block-list">
<li><strong>Reduce operating costs: it allows you</strong> to switch to targeted service based on actual status instead of fixed time revisions, which can be inefficient.</li>



<li><strong>Investment optimisation: accurate</strong> data on wear rates and residual lifetime allows managers to better plan infrastructure renewal and avoid premature purchases of new machines.</li>



<li><strong>Enhancing safety and ecology: continuous</strong> monitoring minimizes the risk of catastrophic failures, fires or environmental accidents associated with oil spills.</li>
</ul>

<p>In today&#8217;s power industry, <strong>investing in</strong> <strong>transformer monitoring is</strong> a necessary step to ensure business continuity. At a time of long lead times for new technologies and high energy costs, keeping existing infrastructure in tip-top shape is the most effective route to grid sustainability and stability. </p>
<p>Článok <a href="https://www.bez.sk/en/blog/diagnostics-and-monitoring-of-transformers-fault-prevention/">Diagnostics and monitoring of transformers: fault prevention</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Low-loss transformers: modern technologies and materials</title>
		<link>https://www.bez.sk/en/blog/low-loss-transformers-modern-technologies-and-materials/</link>
		
		<dc:creator><![CDATA[Copy Digitalman]]></dc:creator>
		<pubDate>Wed, 17 Dec 2025 10:06:36 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[Types of transformers]]></category>
		<category><![CDATA[Výkon transformátorov]]></category>
		<category><![CDATA[druhy transformátorov]]></category>
		<category><![CDATA[dry transformer]]></category>
		<category><![CDATA[oil transformer]]></category>
		<category><![CDATA[straty transformátora]]></category>
		<category><![CDATA[transformer]]></category>
		<category><![CDATA[transformer performance]]></category>
		<guid isPermaLink="false">https://www.bez.sk/blog/low-loss-transformers-modern-technologies-and-materials/</guid>

					<description><![CDATA[<p>Low-loss transformers and energy efficiency have become a global priority. In particular, the focus is on minimising losses. Every percentage reductio...</p>
<p>Článok <a href="https://www.bez.sk/en/blog/low-loss-transformers-modern-technologies-and-materials/">Low-loss transformers: modern technologies and materials</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>Low-loss transformers and energy efficiency have become a global priority. In particular, the focus is on minimising losses. Every percentage reduction in losses translates into massive energy savings at the level of the entire distribution network, which has a direct economic and environmental impact. Lower losses not only mean lower operating costs, but also a significant reduction in CO   </strong><strong><sub>2</sub></strong><strong>  and less burden on the environment. This trend has also been formalised legislatively, notably through the stringent Commission Regulation (EU) 2019/1783 (Ecodesign 2021, Stage 2), which sets uncompromising requirements for transformer losses.   </strong></p>

<h2 class="wp-block-heading"><strong>Understanding transformer losses</strong></h2>

<p>We divide transformer losses into two main groups, which have different sources and require different design solutions.  </p>

<h3 class="wp-block-heading"><strong>1. Idle losses (iron losses)</strong></h3>

<p>These losses occur in <strong>the magnetic core of the transformer</strong>. They are constant and <strong>do not depend on the load.</strong> <a href="https://www.bez.sk/en/transformers-in-stock/" target="_blank" rel="noreferrer noopener">They are consumed by the transformer </a>whenever it is connected to the grid, even if it is not transmitting any power. <strong>Hysteresis losses are caused by </strong>the constant change in the direction of the magnetic field (remagnetization) of the core material. They are related to the quality of the magnetic sheets and their loss characteristics. <strong>Eddy current losses are due to </strong>induced currents directly in the core material, which are generated by the variable magnetic flux. They are reduced by dividing the core into thin insulated sheets (lamination).   </p>

<h3 class="wp-block-heading">2. <strong>Short-circuit losses (losses in windings)</strong></h3>

<p>Short-circuit losses mainly occur in <strong>the transformer winding</strong> (in copper or aluminum). These losses are directly related to the magnitude of the current flowing through the transformer and are therefore <g id="gid_1">load dependent.</g> They are caused by <g id="gid_2">the winding resistance</g>. As the load on the transformer increases, the current increases and the losses increase with the square of the current.     </p>

<h2 class="wp-block-heading"><strong>Innovative materials for loss reduction in low-loss transformers  </strong></h2>

<p>The key to radically reducing both types of loss lies in the selection and processing of superior materials. <span class="notranslate">BEZ TRANSFORMÁTORY, we use</span> top-quality steel with <strong>a grain-oriented structure (CRGO) that ensures</strong> easy passage of the magnetic flux. These cores also utilize advanced sheet metal shearing and folding technology, such as <strong>step-lap, which</strong> minimizes transient resistive losses at the corners.  </p>

<p>The amorphous metal material has <strong>an unstructured atomic structure,</strong> similar to glass. The lack of a crystalline structure reduces the energy required to remagnetize the material, resulting in extremely low hysteresis losses. Low-loss transformers with an amorphous metal core can <strong>reduce no-load losses by up to 66% compared</strong> to conventional CRGO steel, delivering unmatched standby efficiency. We use either copper, which has an extremely low resistivity, or aluminium, which offers a favourable price/performance ratio, in the manufacture of the windings. The key is to use conductors with <strong>the ideal cross-section with respect </strong>to the current flowing through them. A larger cross-section naturally reduces resistance and therefore heat loss. Optimizing the cross-section of the conductors becomes the most important design element in the fight against load losses.      </p>

<figure class="wp-block-image size-full"><img decoding="async" width="2000" height="1334" src="https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami.jpg" alt="low-loss transformers, innovative materials, loss reduction" class="wp-image-11075" srcset="https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-705x470.jpg 705w" sizes="(max-width: 2000px) 100vw, 2000px" /></figure>

<p></p>

<h2 class="wp-block-heading"><strong>Advanced technologies and design solutions for low-loss transformers  </strong></h2>

<p>Low losses are not just a matter of materials, but also require precise design and manufacturing technologies to ensure optimum use of these superior raw materials. We use advanced shearing lines with <strong>Step-Lap</strong> technology to produce magnetic cores. This method ensures extremely precise lamella joints at the corners of the core, minimizing air gaps and reducing local eddy current and hysteresis losses at magnetic flux bending points.  </p>

<p>The winding design, especially for power transformers, must minimize stray <strong>losses.</strong> These are additional losses caused by leakage magnetic flux that induces currents in the surrounding metal parts of the transformer (e.g. clamping frames). We use special shielding and optimize the spatial arrangement of the windings to direct the flux and suppress these unwanted losses.  </p>

<p><a href="https://www.bez.sk/en/dry-transformers/" target="_blank" rel="noreferrer noopener">Low-loss dry-type transformers</a> with cast insulation represent a modern alternative to traditional oil-cooled transformers and bring significant low-loss and safety benefits. Instead of flammable oil, they use <strong>epoxy resin (</strong> EP) to pot the windings. This resin is environmentally friendly, flame retardant and reduces the risk of fire, thereby increasing the safety of operation. Cast insulation technology allows more precise placement of windings, minimizing internal resistance and increasing mechanical stability.     </p>

<p>Proper heat dissipation is also key. Higher operating temperature increases winding resistance, which directly leads to an increase in short-circuit losses. We therefore use efficient natural or forced cooling systems to keep the transformer at optimum operating temperature. We ensure maximum flow of coolant (air or oil) around the windings and core, thus achieving a stable low temperature and the transformer consistently operates under the lowest possible loss conditions.   </p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2000" height="1334" src="https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-2.jpg" alt="low-loss transformers, advanced technology" class="wp-image-11079" srcset="https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-2.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-2-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-2-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-2-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-2-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-2-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/12/transformatory-s-nizkymi-stratami-2-705x470.jpg 705w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /></figure>

<p></p>

<h2 class="wp-block-heading"><strong>Eco-design and the future of low-loss transformers  </strong></h2>

<p>For <span class="notranslate">BEZ TRANSFORMÁTORY</span>, meeting the EU&#8217;s Ecodesign requirements <span class="notranslate">is</span> a minimum standard, not a target. Our innovations in materials and design ensure that our <strong><a href="https://www.bez.sk/en/transformers-in-stock/" target="_blank" rel="noreferrer noopener">low-loss transformers</a></strong> not only meet the strict loss limits in place from 2021 (Stage 2), but many even exceed them, providing our clients with future-ready solutions.   </p>
<p>Článok <a href="https://www.bez.sk/en/blog/low-loss-transformers-modern-technologies-and-materials/">Low-loss transformers: modern technologies and materials</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Transformers in photovoltaics: choosing the right transformer for maximum efficiency of a photovoltaic power plant</title>
		<link>https://www.bez.sk/en/blog/transformers-in-photovoltaics-choosing-the-right-transformer-for-maximum-efficiency-of-a-photovoltaic-power-plant/</link>
		
		<dc:creator><![CDATA[Copy Digitalman]]></dc:creator>
		<pubDate>Fri, 28 Nov 2025 17:30:06 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[Types of transformers]]></category>
		<category><![CDATA[dry transformer]]></category>
		<category><![CDATA[oil transformer]]></category>
		<category><![CDATA[transformer]]></category>
		<category><![CDATA[transformer performance]]></category>
		<category><![CDATA[transformers for renewable energy]]></category>
		<guid isPermaLink="false">https://www.bez.sk/blog/transformers-in-photovoltaics-choosing-the-right-transformer-for-maximum-efficiency-of-a-photovoltaic-power-plant/</guid>

					<description><![CDATA[<p>Discussions of green energy often focus on photovoltaic panels, which convert sunlight into electricity, and inverters, which transform direct current...</p>
<p>Článok <a href="https://www.bez.sk/en/blog/transformers-in-photovoltaics-choosing-the-right-transformer-for-maximum-efficiency-of-a-photovoltaic-power-plant/">Transformers in photovoltaics: choosing the right transformer for maximum efficiency of a photovoltaic power plant</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>Discussions of green energy often focus on photovoltaic panels, which convert sunlight into electricity, and inverters, which transform direct current into alternating current. While these components are crucial, there is another and often overlooked link in the chain between the PV array and our homes or industrial plants: the transformer. But transformers in PV are not limited to raising the voltage.  </strong></p>

<h2 class="wp-block-heading"><strong>The role of transformers in photovoltaic power plants</strong></h2>

<p>Photovoltaic systems, whatever their size, have a fundamental challenge: the energy they generate must be adapted to meet the stringent requirements of the electricity grid.</p>

<h3 class="wp-block-heading"><strong>Increasing tension</strong></h3>

<p>Photovoltaic panels produce direct current (DC), which the inverter then converts to alternating current (AC). However, this AC current is generated at a relatively low voltage. While this would be sufficient for normal domestic use, it is inefficient and uneconomical for transmission over medium and long distances to distribution points. Therefore, a transformer comes into play. It receives AC current from inverters and its main task is to radically increase the voltage to grid level (e.g. 22 kV, 35 kV, or up to 110 kV for large parks). Without this step, there would be huge energy losses. This is because higher voltages allow power to be transmitted at a much lower amperage, thus minimising losses in the lines.      </p>

<h3 class="wp-block-heading"><strong>Insulation and system safety</strong></h3>

<p>The transformer also performs a safety function. It provides galvanic isolation of the photovoltaic system from the distribution network. This decoupling protects the expensive and sensitive inverters from surges, surges and faults that can occur on the grid, while ensuring that faults in the solar park do not critically affect the stability of the utility grid.  </p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2121" height="1414" src="https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-3.jpg" alt="transformer in photovoltaics" class="wp-image-10904" srcset="https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-3.jpg 2121w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-3-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-3-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-3-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-3-1536x1024.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-3-2048x1365.jpg 2048w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-3-1500x1000.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-3-705x470.jpg 705w" sizes="auto, (max-width: 2121px) 100vw, 2121px" /></figure>

<p></p>

<h2 class="wp-block-heading"><strong>Typology of transformers in photovoltaic systems</strong></h2>

<p><span class="notranslate">BEZ TRANSFORMÁTORY offers</span> two main types of transformers for photovoltaic parks: oil-immersed and dry-type transformers.</p>

<h3 class="wp-block-heading"><strong>Oil Transformers for Renewable Energy</strong></h3>

<p><a href="https://www.bez.sk/en/transformers-for-renewable-energy/" target="_blank" rel="noreferrer noopener">Oil-cooled transformers are</a> cooled by mineral oil and are the most widely used type in the long term, particularly suitable for outdoor PV park environments where they can withstand adverse weather conditions. Thanks to oil cooling, they can dissipate heat efficiently even under higher loads and offer excellent reliability and extended service life. </p>

<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="933" height="1030" src="https://www.bez.sk/wp-content/uploads/2025/03/Olejovy_transformator-933x1030.png" alt="oil transformer" class="wp-image-3224" srcset="https://www.bez.sk/wp-content/uploads/2025/03/Olejovy_transformator-933x1030.png 933w, https://www.bez.sk/wp-content/uploads/2025/03/Olejovy_transformator-272x300.png 272w, https://www.bez.sk/wp-content/uploads/2025/03/Olejovy_transformator-768x848.png 768w, https://www.bez.sk/wp-content/uploads/2025/03/Olejovy_transformator-638x705.png 638w, https://www.bez.sk/wp-content/uploads/2025/03/Olejovy_transformator.png 1132w" sizes="auto, (max-width: 933px) 100vw, 933px" /></figure>

<h2 class="wp-block-heading"><strong>Dry-type transformers for renewable energies</strong></h2>

<p><a href="https://www.bez.sk/en/transformers-for-renewable-energy/" target="_blank" rel="noreferrer noopener">Dry-type transformers do not use</a> liquid dielectric, but are cooled by air. They are ideal for indoor and container stations where there are increased demands on fire safety, for example in close proximity to inverters or in densely built-up areas. They are more environmentally friendly, require less maintenance and eliminate the risk of oil leaks.    </p>

<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1028" height="1030" src="https://www.bez.sk/wp-content/uploads/2025/03/Suchy_transformator-1028x1030.jpeg" alt="dry transformer" class="wp-image-3218" srcset="https://www.bez.sk/wp-content/uploads/2025/03/Suchy_transformator-1028x1030.jpeg 1028w, https://www.bez.sk/wp-content/uploads/2025/03/Suchy_transformator-300x300.jpeg 300w, https://www.bez.sk/wp-content/uploads/2025/03/Suchy_transformator-80x80.jpeg 80w, https://www.bez.sk/wp-content/uploads/2025/03/Suchy_transformator-768x769.jpeg 768w, https://www.bez.sk/wp-content/uploads/2025/03/Suchy_transformator-36x36.jpeg 36w, https://www.bez.sk/wp-content/uploads/2025/03/Suchy_transformator-180x180.jpeg 180w, https://www.bez.sk/wp-content/uploads/2025/03/Suchy_transformator-705x705.jpeg 705w, https://www.bez.sk/wp-content/uploads/2025/03/Suchy_transformator-575x575.jpeg 575w, https://www.bez.sk/wp-content/uploads/2025/03/Suchy_transformator.jpeg 1248w" sizes="auto, (max-width: 1028px) 100vw, 1028px" /></figure>

<h2 class="wp-block-heading"><strong>Impact of transformers on the efficiency and stability of power transmission</strong></h2>

<p>The quality of the transformer directly determines the economic success and technical reliability of the entire solar project.</p>

<h3 class="wp-block-heading"><strong>Efficiency and loss minimisation</strong></h3>

<p>As we have already mentioned, loss minimisation is a key factor. This is because by increasing the voltage, the current drops, which dramatically reduces the heat loss. <a href="https://www.bez.sk/en/transformers-for-renewable-energy/" target="_blank" rel="noreferrer noopener">Transformers with</a> low intrinsic losses maximize the amount of energy produced that actually reaches the consumer. Thanks to their robust design and life expectancy in excess of 30 years, transformers guarantee a long-term return on investment and reliable operation of the PV park in a variety of climatic and operating conditions. The investment in a transformer with low no-load and short-circuit losses will thus pay for itself many times over during the long lifetime of the project.   </p>

<h3 class="wp-block-heading"><strong>Network stability and quality control</strong></h3>

<p>Photovoltaics, although a clean source, can present challenges in the form of voltage fluctuations and THD harmonic distortion generated by inverters. Therefore, advanced transformers have systems that allow smooth and automatic voltage regulation, thus maintaining grid stability even with rapid changes in sunshine. In addition, the transformer helps to dampen and filter harmonic currents. This ensures that the energy supplied to the distribution system is clean and meets all standards.   </p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2414" height="1241" src="https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-2.jpg" alt="transformer in photovoltaic power plant" class="wp-image-10908" srcset="https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-2.jpg 2414w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-2-300x154.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-2-1030x530.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-2-768x395.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-2-1536x790.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-2-2048x1053.jpg 2048w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-2-1500x771.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/11/Transformatory-vo-fotovoltike-2-705x362.jpg 705w" sizes="auto, (max-width: 2414px) 100vw, 2414px" /></figure>

<p></p>

<h2 class="wp-block-heading"><strong>The challenge of the future</strong></h2>

<p>As PV expands and integrates into smart grids and battery storage, the demands on transformers will only increase. Their quality design, ability to handle fluctuating loads and minimize losses are essential for a successful and sustainable transition to green energy. </p>

<p>If you are currently designing or optimizing your PV park and are looking for a customized solution that guarantees low losses and long lifetime, <a href="https://www.bez.sk/en/contact/" target="_blank" rel="noreferrer noopener">contact us.</a> Our technical specialists will be happy to help you with your selection. </p>
<p>Článok <a href="https://www.bez.sk/en/blog/transformers-in-photovoltaics-choosing-the-right-transformer-for-maximum-efficiency-of-a-photovoltaic-power-plant/">Transformers in photovoltaics: choosing the right transformer for maximum efficiency of a photovoltaic power plant</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Transformer life: how to extend its operation?</title>
		<link>https://www.bez.sk/en/blog/zivotnost-transformatora-ako-predlzit-jeho-prevadzku/</link>
		
		<dc:creator><![CDATA[Copy Digitalman]]></dc:creator>
		<pubDate>Fri, 28 Nov 2025 17:01:22 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[výmena transformátorov]]></category>
		<category><![CDATA[transformer]]></category>
		<category><![CDATA[transformer replacement]]></category>
		<category><![CDATA[životnosť transformátora]]></category>
		<guid isPermaLink="false">https://www.bez.sk/blog/zivotnost-transformatora-ako-predlzit-jeho-prevadzku/</guid>

					<description><![CDATA[<p>Technical, operational and environmental factors determine how long a plant will operate reliably. Deteriorated insulation, overloading or inadequate...</p>
<p>Článok <a href="https://www.bez.sk/en/blog/zivotnost-transformatora-ako-predlzit-jeho-prevadzku/">Transformer life: how to extend its operation?</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>Technical, operational and environmental factors determine how long a plant will operate reliably. Deteriorated insulation, overloading or inadequate maintenance can lead to reduced performance, higher losses and ultimately premature failure. Thus, reduced transformer lifetime is not just a technical problem. It also represents a significant financial loss, as the replacement or overhaul of equipment is one of the most costly interventions in the electricity industry.   </strong></p>

<h2 class="wp-block-heading"><strong>Factors affecting transformer life</strong></h2>

<p>Transformer life is the result of the interplay of a number of physical, chemical and operational phenomena. The following factors are among the most significant. </p>

<h3 class="wp-block-heading"><strong>Thermal stress and overload</strong></h3>

<p>If the equipment is operated at a higher temperature than specified by the manufacturer for an extended period of time, the degradation of insulation materials is accelerated. Therefore, make sure that <g id="gid_0">the transformer</g> is <g id="gid_0">properly</g> sized and avoid overloading it for long periods of time. Even short-term overloading can leave lasting effects if repeated too often.  </p>

<h3 class="wp-block-heading"><strong>Quality of the insulation system</strong></h3>

<p>If the condition of the insulation system deteriorates, not only the electrical strength but also the overall service life of the transformer is reduced. The most common problems are moisture, oil oxidation and contamination by dirt. For this reason, regularly check the physicochemical properties of the insulating oil. Prevention in this case is much cheaper than subsequent repair.   </p>

<h3 class="wp-block-heading"><strong>Vibration and mechanical stress</strong></h3>

<p>Prolonged vibration can lead to loosening of windings, damage to connections and weakening of the core. Proper design is therefore the basis for a long service life. In practice, it is recommended to check the fit of the screws and damping elements regularly, especially after major short circuits or equipment transports.  </p>

<h3 class="wp-block-heading"><strong>Influence of the external environment</strong></h3>

<p>Dust, moisture, corrosive environments or extreme temperatures can accelerate the ageing of materials and reduce insulation properties. In addition, transformers located outdoors are exposed to sudden changes in temperature, UV radiation and weathering. Therefore, use appropriate protective coatings, seals and filtration systems. Proper ventilation and regular leakage checks are also important, especially for oil-immersed transformers.   </p>

<h3 class="wp-block-heading"><strong>Quality of installation and pre-commissioning checks</strong></h3>

<p>Improper cable connections, loose contacts or neglected cooling can significantly shorten the operating life of the transformer. The key is therefore <a href="https://www.bez.sk/en/supervised-installation/" target="_blank" rel="noreferrer noopener">professional installation,</a> careful checking before start-up and adherence to the manufacturer&#8217;s recommendations throughout the lifetime of the transformer. </p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2000" height="1334" src="https://www.bez.sk/wp-content/uploads/2025/11/PF__2022.jpg" alt="Factors Affecting Transformer Lifetime, Quality of Installation and Inspection Before Starting&#10;&#10;" class="wp-image-10891" srcset="https://www.bez.sk/wp-content/uploads/2025/11/PF__2022.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/11/PF__2022-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/11/PF__2022-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/11/PF__2022-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/11/PF__2022-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/11/PF__2022-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/11/PF__2022-705x470.jpg 705w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /></figure>

<p></p>

<h2 class="wp-block-heading"><strong>Inspections and revisions as the key to long transformer life</strong></h2>

<p>Even the best quality transformer needs regular checks and inspections. A properly set up inspection program can extend the life of a transformer by decades while increasing its efficiency by reducing energy losses and minimizing the risk of failure. Inspections and revisions should include the following steps:  </p>

<ul class="wp-block-list">
<li>oil tightness check,</li>



<li>analysis of oils and gases,</li>



<li>electrical testing, protection calibration and transformer earthing,</li>



<li>control of noise, vibration and ambient temperature,</li>



<li>correct setting and securing of the tap changer.</li>
</ul>

<p>The investment in inspections and revisions always pays off in lower operating costs, higher transformer efficiency and, above all, a longer and more reliable service life.</p>

<h2 class="wp-block-heading"><strong>Preventive measures to reduce wear</strong></h2>

<p>Although the transformer has its design limits, the right approach can significantly extend its life and maintain high efficiency throughout operation. Preventive measures do not only mean regular inspections, but also strategic decisions on operating methods, upgrades and operator behaviour: </p>

<ul class="wp-block-list">
<li>proper operation and load management,</li>



<li>modernisation and technical improvements,</li>



<li>temperature and humidity control,</li>



<li>operator training and competence,</li>



<li>strategic planning and predictive maintenance.</li>
</ul>

<p>Preventive measures are not just a set of technical steps, but an overall philosophy of how to approach a facility. If applied consistently, they can extend the life of a transformer by decades while reducing both energy and service costs. </p>
<p>Článok <a href="https://www.bez.sk/en/blog/zivotnost-transformatora-ako-predlzit-jeho-prevadzku/">Transformer life: how to extend its operation?</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Transformer voltage transformer: key role and practical application</title>
		<link>https://www.bez.sk/en/blog/prevod-napatia-transformatorom-klucova-uloha-a-prakticke-vyuzitie/</link>
		
		<dc:creator><![CDATA[Copy Digitalman]]></dc:creator>
		<pubDate>Tue, 04 Nov 2025 13:23:56 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[Types of transformers]]></category>
		<category><![CDATA[distributed transformers]]></category>
		<category><![CDATA[druhy transformátorov]]></category>
		<category><![CDATA[transformačný pomer]]></category>
		<category><![CDATA[transformer]]></category>
		<category><![CDATA[transformer performance]]></category>
		<category><![CDATA[zvyšovacie transformátory]]></category>
		<guid isPermaLink="false">https://www.bez.sk/blog/prevod-napatia-transformatorom-klucova-uloha-a-prakticke-vyuzitie/</guid>

					<description><![CDATA[<p>Without transformers, electricity could not travel efficiently and safely from the power station to your socket, nor would most industrial machinery w...</p>
<p>Článok <a href="https://www.bez.sk/en/blog/prevod-napatia-transformatorom-klucova-uloha-a-prakticke-vyuzitie/">Transformer voltage transformer: key role and practical application</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>Without transformers, electricity could not travel efficiently and safely from the power station to your socket, nor would most industrial machinery work. But all functionality depends on one key principle. It is voltage conversion.  </strong></p>

<h2 class="wp-block-heading"><strong>How transformers change voltage level</strong></h2>

<p>A transformer is essentially a static device that transfers electrical energy from one circuit to another without direct electrical contact, using a magnetic field. <strong>The principle of electromagnetic induction</strong> is the basis for voltage transfer in a transformer <strong>,</strong> <strong> </strong>discovered by Michael Faraday. When an alternating current passes through the primary winding, it creates a constantly changing magnetic field in the core. This changing field passes through the secondary winding and induces a voltage in it. What the output voltage level will be depends entirely on the ratio of the number of turns of the primary and secondary windings. This relationship defines the key parameter of the transformer: <strong>the transformation ratio.</strong>    </p>

<h2 class="wp-block-heading"><strong>Voltage units and conversion of voltage units</strong></h2>

<p>When discussing voltage conversion, we cannot avoid the fundamental physical quantity: electrical voltage. The basic unit of electrical voltage in a system is the volt, named after the Italian physicist Alessandro Volta. The conversion or transformation of voltage units is, of course, necessary for the precise design and operation of networks. When we need to determine what voltage a transformer will handle, we always work in consistent units: volts, millivolts, kilovolts or megavolts.   </p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2000" height="1334" src="https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-3.jpg" alt="step-up and distribution transformers" class="wp-image-10337" srcset="https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-3.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-3-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-3-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-3-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-3-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-3-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-3-705x470.jpg 705w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /></figure>

<p></p>

<h2 class="wp-block-heading"><strong>From mains to USB charger</strong></h2>

<p>The role of transformers is divided into two main categories: strategic (in the power sector) and local (in industry and households). <a href="https://www.bez.sk/en/transformers-in-stock/" target="_blank" rel="noreferrer noopener">BEZ TRANSFORMÁTORY, we specialize</a> in distribution transformers, which are critical in the transition between the grid and the end consumer. </p>

<p>The key reason for voltage transfer is to minimize transmission losses. The higher the voltage, the lower the current, and the lower the heat losses on the lines. <strong>Boosting transformers</strong> operate in the vicinity of power plants <strong>.</strong> Electricity is generated at lower voltages (e.g. 10-25 kV). Step-up transformers immediately convert it to very high transmission voltages (e.g. 110 kV, 220 kV, 400 kV) for efficient long-distance transmission. As the power approaches populated areas, <g id="gid_1">distribution transformers</g> step in <g id="gid_1">.</g> These carry out a gradual step-down.      </p>

<p>In the industrial environment, voltage conversion is important for powering specific machines and improving safety. Finally, also in solar parks and wind turbines, <a href="https://www.bez.sk/en/transformers-for-renewable-energy/" target="_blank" rel="noreferrer noopener">transformers raise</a> the generated voltage to grid level so that it can be distributed efficiently. </p>

<p>Transformers are part of your life all the time. For example, you will find a distribution transformer in front of your house that reduces the voltage from 22 kV to the standard 230 V for your home. Most of the home voltage transfer is then provided by small adaptors (which contain miniature transformers or electronic switching power supplies). Almost every device that does not run directly on 230 V (mobile phone chargers, laptop chargers, LED lighting) needs a step-down transformer or electronic substitute to safely reduce the voltage (e.g. from 230 V to 5 V for USB or 12 V for lighting).   </p>

<h2 class="wp-block-heading"><strong>Voltage transfer is more than just a technical operation</strong></h2>

<p>It is the pillar on which modern electricity infrastructure stands. It allows us to transmit electricity with minimal losses while delivering it safely to every device, from a huge production line to the smallest LED bulb. </p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2000" height="1232" src="https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-2.jpg" alt="voltage transfer by transformer" class="wp-image-10333" srcset="https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-2.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-2-300x185.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-2-1030x634.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-2-768x473.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-2-1536x946.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-2-1500x924.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/11/prevod-napatia-2-705x434.jpg 705w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /></figure>

<p><a href="https://www.bez.sk/en/about-us/" target="_blank" rel="noreferrer noopener">As the only manufacturer of distribution transformers in Slovakia with more than 120 years of tradition, BEZ TRANSFORMÁTORY</a> ensures that this critical voltage transfer takes place reliably and efficiently throughout the distribution network, making it a key link in the stability of the energy infrastructure.<br/></p>
<p>Článok <a href="https://www.bez.sk/en/blog/prevod-napatia-transformatorom-klucova-uloha-a-prakticke-vyuzitie/">Transformer voltage transformer: key role and practical application</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to calculate transformer parameters</title>
		<link>https://www.bez.sk/en/blog/vypocet-transformatora/</link>
		
		<dc:creator><![CDATA[Copy Digitalman]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 17:02:46 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[Výkon transformátorov]]></category>
		<category><![CDATA[druhy transformátorov]]></category>
		<category><![CDATA[transformačný pomer]]></category>
		<category><![CDATA[transformer]]></category>
		<category><![CDATA[transformer performance]]></category>
		<guid isPermaLink="false">https://www.bez.sk/blog/vypocet-transformatora/</guid>

					<description><![CDATA[<p>Do you know how to calculate the transformer needed? Correct calculation is the basis for reliable operation, long life and high efficiency. In order...</p>
<p>Článok <a href="https://www.bez.sk/en/blog/vypocet-transformatora/">How to calculate transformer parameters</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>Do you know how to calculate the transformer needed? Correct calculation is the basis for reliable operation, long life and high efficiency. In order for it to work optimally, you need to know exactly its transformation ratio, power, efficiency and losses. However, it is important to understand the basic relationships behind the calculations themselves, whether it is to determine the number of turns, the winding voltage or the power parameters. We therefore bring you a practical step-by-step guide explaining how to calculate a transformer and how to calculate the basic transformer parameters, from transformation ratio to efficiency and losses.    </strong></p>

<h2 class="wp-block-heading"><strong>Basic concepts before transformer calculation</strong></h2>

<p>Before getting into the actual calculation of the transformer, it is important to understand a few basic concepts and relationships that determine its behavior.</p>

<h3 class="wp-block-heading"><strong>Primary and secondary winding voltage</strong></h3>

<p><a href="https://www.bez.sk/en/transformers-in-stock/" target="_blank" rel="noreferrer noopener">The transformer has</a> two main parts. <strong>A primary winding,</strong> to which the input voltage U1 is connected, and <strong>a secondary winding, from which</strong> the output voltage U2 is taken. The ratio between these two voltages determines <strong>the</strong> so-called <strong>transformation ratio (conversion), which is</strong> a <strong>basic</strong> parameter of every transformer: </p>

<ul class="wp-block-list">
<li>If U1&gt;<strong>U2, it is a step-down (voltage) transformer</strong>.</li>



<li>If U1&lt;U2 <strong>, we are talking about a step-up transformer</strong>.</li>
</ul>

<h3 class="wp-block-heading"><strong>Transformer current and power</strong></h3>

<p>The current in the primary winding is denoted by I1 and in the secondary winding by I2. For an ideal transformer, the power at the input and output is the same. However, in a real transformer, some of the power is lost due to thermal and magnetic losses, so the output power is always slightly less than the input power.  </p>

<h3 class="wp-block-heading"><strong>Transformer efficiency</strong></h3>

<p>Efficiency (η) expresses how efficiently the transformer converts energy. It is defined as the ratio of output to input power: η =<g id="gid_0">Pout/Pin</g><g id="gid_1">× </g>100 %. High quality transformers, such as those manufactured by BEZ <strong>TRANSFORMÁTORY, achieve</strong> efficiencies <strong>of 98-99%, reducing</strong> operating costs and thermal loads.  </p>

<h3 class="wp-block-heading"><strong>Transformer losses  </strong></h3>

<p>The losses can be divided into two main groups:</p>

<ul class="wp-block-list">
<li><strong>Stray losses (in iron) occur</strong> in the transformer core due to magnetic phenomena (hysteretic and eddy currents).</li>



<li><strong>Short-circuit losses (in the windings) are due to</strong> the resistance of the windings, in which some of the energy is converted to heat.</li>
</ul>

<p>Accurate <strong>calculation of transformer losses is</strong> important to determine its efficiency, cooling capacity and economic operation.</p>

<h3 class="wp-block-heading"><strong>Types of transformers by application  </strong></h3>

<p>Before the actual calculation, it is also necessary to know the purpose of the transformer, because the method of calculation depends on it:</p>

<ul class="wp-block-list">
<li><strong>Single-phase transformers are</strong> common in smaller equipment and power supplies.</li>



<li><strong>Three-phase transformers are</strong> used in power and industrial applications.</li>



<li><strong>Measuring transformers are</strong> designed for accurate current or voltage measurements.</li>



<li><strong>Power transformers transmit</strong> high power in electrical networks.</li>
</ul>

<p>These concepts form the basis without which <strong>the transformer calculation</strong> would <strong>not be</strong> accurate or understandable.</p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2000" height="1334" src="https://www.bez.sk/wp-content/uploads/2025/10/PF__1168.jpg" alt="transformer calculation" class="wp-image-9908" srcset="https://www.bez.sk/wp-content/uploads/2025/10/PF__1168.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1168-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1168-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1168-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1168-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1168-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1168-705x470.jpg 705w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /></figure>

<p></p>

<h2 class="wp-block-heading"><strong>Calculation of the transformation ratio</strong></h2>

<p>One of the basic parameters that determine the behavior of the transformer is <strong>the transformation ratio.</strong> This ratio indicates <strong>how many times the voltage between the primary and secondary windings changes</strong>. </p>

<p>The transformation ratio (k) is determined by the formula: k = U1/U2 <em>=<sub>N1/N2</sub>,<sub>where</sub>:</em></p>

<ul class="wp-block-list">
<li>U1<sub>=</sub> primary winding voltage (V)</li>



<li>U2<sub>=</sub> voltage on the secondary winding (V)</li>



<li>N1<sub>= </sub> number of turns of the primary winding</li>



<li>N2<sub>= </sub> number of turns of the secondary winding</li>
</ul>

<p>This relationship shows that the ratio of stresses is <strong>the same as the ratio of the number of turns.</strong> So, for example, if we want to reduce the voltage by a factor of ten, the secondary winding must have ten times fewer turns than the primary. </p>

<h3 class="wp-block-heading"><strong>Application of transformation ratio calculation in practice</strong></h3>

<p>Calculating the ratio helps determine the number of turns of the windings and the cross section of the core. By verifying the transformation ratio, it can be determined whether the device is in order or has a damaged winding. Modern software and online calculators make it possible to quickly determine the correct transformation ratio without manual calculations.  </p>

<p>Almost all transformers also have a tap changer that allows you to vary the voltage on the primary side, normally between -5% and +5%.  <strong>By changing the tap, you can keep the secondary voltage constant.  </strong>Such regulation can be in an off load or on load state. Transformers with an OLTC on-load tap changer are installed at locations with frequent voltage changes on the primary side. The demand for these transformers is increasing due to the renewable resources connected to the distribution grids.  <br/></p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2000" height="1334" src="https://www.bez.sk/wp-content/uploads/2025/10/PF__1143a-plna-kvalita.jpg" alt="transformer calculation" class="wp-image-9912" srcset="https://www.bez.sk/wp-content/uploads/2025/10/PF__1143a-plna-kvalita.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1143a-plna-kvalita-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1143a-plna-kvalita-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1143a-plna-kvalita-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1143a-plna-kvalita-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1143a-plna-kvalita-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/10/PF__1143a-plna-kvalita-705x470.jpg 705w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /></figure>

<blockquote class="wp-block-quote is-layout-flow wp-block-quote-is-layout-flow">
<p><strong><em>Recommendation of the experts from BEZ TRANSFORMÁTORY</em></strong></p>



<p><em>When designing or checking the transformer, always compare the calculated transformation ratio with </em><strong><em>the nominal data on the label</em></strong><em>. Deviations may indicate wear or a fault in the winding.  </em></p>
</blockquote>

<h2 class="wp-block-heading"><strong>Calculation of transformer power</strong></h2>

<p>The <strong>transformer power rating determines</strong> how much electricity the device can transfer from the primary circuit to the secondary circuit without excessive heating or losses. This parameter is critical in both the design and selection of a suitable transformer for a particular application. </p>

<p>The basic relationship for the apparent power of a transformer is S <em>= U × I,</em> where:</p>

<ul class="wp-block-list">
<li>S = apparent power (VA or kVA)</li>



<li>U = voltage (V)</li>



<li>I = current (A)</li>
</ul>

<p>This formula expresses <strong>the output of one phase.</strong> For <strong>a three-phase transformer</strong>, the power <strong>is</strong> calculated as follows. </p>

<p>The result is most often given in <strong>kilovolt-amperes (kVA), which represents</strong> the rated power of the transformer.</p>

<h3 class="wp-block-heading"><strong>How to determine the required transformer power</strong></h3>

<p>When designing or selecting a transformer, it is necessary to take into account:</p>

<ul class="wp-block-list">
<li><strong>the sum of the outputs of all connected devices,</strong></li>



<li><strong>power reserve:</strong> it is recommended to increase the rated power by 10-20%,</li>



<li><strong>nature of the load:</strong> continuous, intermittent or impact,</li>



<li><strong>power factor and operating conditions (</strong> e.g. ambient temperature, cooling).</li>
</ul>

<p>When deciding on power, evaluate efficiency, as transformers reach their highest efficiency at loads between 40-60% of rated power.</p>

<p>Properly selected power ensures stable operation and minimizes thermal stress on the windings. Transformer power is a key parameter that affects its size, weight and operating efficiency. Therefore <strong>,</strong> it is important to perform <strong>an accurate calculation of the transformer at</strong> the design stage and <a href="https://www.bez.sk/en/scouting/" target="_blank" rel="noreferrer noopener">verify it</a> by practical measurement or software simulation.  </p>

<p></p>
<p>Článok <a href="https://www.bez.sk/en/blog/vypocet-transformatora/">How to calculate transformer parameters</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>When is transformer replacement needed?</title>
		<link>https://www.bez.sk/en/blog/kedy-je-potrebna-vymena-transformatora/</link>
		
		<dc:creator><![CDATA[Copy Digitalman]]></dc:creator>
		<pubDate>Tue, 30 Sep 2025 10:23:28 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[výmena transformátorov]]></category>
		<category><![CDATA[transformer]]></category>
		<category><![CDATA[transformer replacement]]></category>
		<guid isPermaLink="false">https://www.bez.sk/blog/kedy-je-potrebna-vymena-transformatora/</guid>

					<description><![CDATA[<p>Every piece of equipment has a lifespan, and after years of operation there comes a point when repairs are no longer enough. By replacing the transfor...</p>
<p>Článok <a href="https://www.bez.sk/en/blog/kedy-je-potrebna-vymena-transformatora/">When is transformer replacement needed?</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>Every piece of equipment has a lifespan, and after years of operation there comes a point when repairs are no longer enough. Replacing the transformer will prevent sudden breakdowns, power outages or unnecessary costs for constant maintenance. In this article, you&#8217;ll learn when it&#8217;s time for replacement, what signs indicate wear and tear, what criteria to consider when making a decision, and how the process of installing a new transformer works.  </strong></p>

<h2 class="wp-block-heading"><strong>Transformer wear symptoms</strong></h2>

<p>Early recognition of warning signals will prevent crashes and costly outages. The most common signs include: </p>

<ul class="wp-block-list">
<li><strong>increased overheating and unusual noise,  </strong></li>



<li><strong>transformer power drop,  </strong></li>



<li><strong>damage to the insulating oil,  </strong></li>



<li><strong>insufficient insulation or leaks,</strong></li>



<li><strong>mechanical damage and corrosion,  </strong></li>



<li><strong>increase in breakdowns and more frequent maintenance.</strong></li>
</ul>

<p>If the transformer exhibits <strong>excessive heating or</strong> makes <strong>unusual noises,</strong> it <strong>may</strong> indicate damage to the windings, core or insulation materials. <strong>A gradual increase in voltage drop, reduced efficiency or</strong> <strong>fluctuations in output parameters indicate</strong> that the transformer can no longer perform its original function. <strong>Oil discolouration, the presence of moisture, odour or visible oil leaks indicate</strong> that the insulation system is losing its properties. <strong>Cracks, rust, damaged terminals or loose connections on the bushings or transformer housing are not only </strong>aesthetic, but especially a serious safety problem.</p>

<p>If the transformer requires regular repairs or faults recur at short intervals, this is a clear sign of approaching end-of-life. In such cases, transformer replacement is often a more economical solution than further investment in repairs. </p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2000" height="1536" src="https://www.bez.sk/wp-content/uploads/2025/09/Kedy-je-potrebna-vymena-transformatora-2.jpg" alt="transformer replacement" class="wp-image-9760" srcset="https://www.bez.sk/wp-content/uploads/2025/09/Kedy-je-potrebna-vymena-transformatora-2.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/09/Kedy-je-potrebna-vymena-transformatora-2-300x230.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/09/Kedy-je-potrebna-vymena-transformatora-2-1030x791.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/09/Kedy-je-potrebna-vymena-transformatora-2-768x590.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/09/Kedy-je-potrebna-vymena-transformatora-2-1536x1180.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/09/Kedy-je-potrebna-vymena-transformatora-2-1500x1152.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/09/Kedy-je-potrebna-vymena-transformatora-2-705x541.jpg 705w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /></figure>

<p></p>

<h2 class="wp-block-heading"><strong>Transformer replacement criteria</strong></h2>

<p>Recognising the signs of wear and tear is only the first step. After that, the actual decision as to whether transformer replacement is necessary depends on a number of factors:   </p>

<ul class="wp-block-list">
<li><strong>the age and service life of the equipment,</strong></li>



<li><strong>economic efficiency,</strong></li>



<li><strong>change in performance requirements,  </strong></li>



<li><strong>norms and safety standards,</strong></li>



<li><strong>Preventive exchange for critical infrastructure.</strong></li>
</ul>

<p>Transformers have <strong>a limited design life, which</strong> is most often in the range of 20-40 years, depending on the type and operating conditions. If the cost of regular repairs and maintenance exceeds the cost of a new unit in the long term, replacement is the logical choice. When the grid is expanded, demand increases or technological changes occur, the existing transformer may not be sufficient. Therefore, <g id="gid_1">installing a new unit with a higher capacity will ensure</g> reliable coverage of future needs. In energy-intensive operations or facilities where <strong>an uninterrupted supply of electricity</strong> is <strong>crucial (hospitals</strong>, data centres, industrial plants), it is often more advantageous to replace the transformer as a precautionary measure than to risk an unplanned outage.    </p>

<p>Newer standards require stricter legislative requirements and environmental regulations. Conversely, older types of transformers may contain insulating oils or materials that no longer meet current environmental and safety standards.   </p>

<p>An old transformer manufactured according to the standards in force at the time has, among other things, higher operating costs. Although the transformer is less loaded, it still draws some energy (no-load losses) to magnetize the core. The cost of such a transformer represents a significant financial cost. In addition, older standards set these losses at much higher levels than the stringent European Union standards in force today, which instruct manufacturers to comply with the <strong>Ecodesign 2 loss</strong> level <strong>on all</strong> newly installed transformers (some exceptions apply). Transformer loss capitalisation is used to calculate transformer payback. Simply put, it is the conversion of technical values (losses) into financial costs.     </p>

<h2 class="wp-block-heading"><strong>The process of installing new equipment</strong></h2>

<p>Transformer replacement itself is not just about dismantling the old equipment and installing the new one. In fact, it is a complex process that requires thorough preparation, expert supervision and precise execution of every step: </p>

<ol class="wp-block-list">
<li><strong>Needs analysis and solution design</strong></li>



<li><strong>Transformer selection and manufacturing</strong></li>



<li><strong>Dismantling old equipment</strong></li>



<li><strong>Installation and testing of the new transformer</strong></li>



<li><strong>Warranty and post-warranty service</strong></li>
</ol>

<p>The first step is <strong>to assess the current and expected electricity consumption.</strong> Modern transformer manufacturing allows <strong>the equipment to be tailored to the customer&#8217;s specific requirements, from</strong> capacity and cooling system to environmentally friendly insulating oil solutions. Once the needs have been assessed, the old transformer is professionally disconnected from the grid and safely dismantled by experts. This step also includes <strong>environmentally friendly disposal or recycling,</strong>  <strong> </strong>that meets applicable environmental standards. Delivery of the new equipment is followed by <a href="https://www.bez.sk/en/supervised-installation/" target="_blank" rel="noreferrer noopener"><strong>installation</strong></a><strong>, connection to the network and carrying out the necessary tests.</strong> <a href="https://www.bez.sk/en/scouting/" target="_blank" rel="noreferrer noopener">Testing includes</a> checking electrical parameters, insulation strength and the functionality of protection systems. After commissioning <strong>, regular maintenance and monitoring of operating parameters</strong> is important <strong>.</strong> <a href="https://www.bez.sk/en/scouting/" target="_blank" rel="noreferrer noopener">Professional servicing prolongs</a> the life of the equipment and reduces the risk of unexpected failures.  </p>

<figure class="wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex">
<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2000" height="1334" data-id="9764" src="https://www.bez.sk/wp-content/uploads/2025/09/profesionalny-servis.jpg" alt="professional transformer service" class="wp-image-9764" srcset="https://www.bez.sk/wp-content/uploads/2025/09/profesionalny-servis.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/09/profesionalny-servis-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/09/profesionalny-servis-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/09/profesionalny-servis-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/09/profesionalny-servis-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/09/profesionalny-servis-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/09/profesionalny-servis-705x470.jpg 705w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /></figure>
</figure>

<p>If your transformer is nearing the end of its useful life or exhibiting any of the above symptoms, <a href="https://www.bez.sk/en/enquiry-form/" target="_blank" rel="noreferrer noopener">don&#8217;t hesitate to contact the professionals.</a> At <strong>BEZ TRANSFORMÁTORY, we provide</strong> a full range of services from needs analysis to custom transformer fabrication to installation and long-term service. We can also provide you with a loss capitalization calculation and therefore when you will recover the cost of a new transformer.    <br/></p>
<p>Článok <a href="https://www.bez.sk/en/blog/kedy-je-potrebna-vymena-transformatora/">When is transformer replacement needed?</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Battery storage: the future of energy</title>
		<link>https://www.bez.sk/en/blog/battery-storage-the-future-of-energy/</link>
		
		<dc:creator><![CDATA[Copy Digitalman]]></dc:creator>
		<pubDate>Tue, 26 Aug 2025 10:25:56 +0000</pubDate>
				<category><![CDATA[Battery storage]]></category>
		<category><![CDATA[Blog]]></category>
		<category><![CDATA[battery storage]]></category>
		<category><![CDATA[dry transformer]]></category>
		<category><![CDATA[oil transformer]]></category>
		<category><![CDATA[special transformers]]></category>
		<category><![CDATA[transformers for renewable energy]]></category>
		<guid isPermaLink="false">https://www.bez.sk/blog/battery-storage-the-future-of-energy/</guid>

					<description><![CDATA[<p>Battery storage is becoming a key element of modern energy networks. They can stabilise the grid, provide back-up power and optimise power flow. They...</p>
<p>Článok <a href="https://www.bez.sk/en/blog/battery-storage-the-future-of-energy/">Battery storage: the future of energy</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>Battery storage is becoming a key element of modern energy networks. They can stabilise the grid, provide back-up power and optimise power flow. They also represent a technical challenge for transformer and power distribution companies. But it is also an opportunity to integrate modern solutions into existing infrastructure. Choosing the right type of storage, its capacity and compatibility with transformers are critical factors for the efficient and reliable operation of any power system.    </strong></p>

<h2 class="wp-block-heading"><strong>The importance of battery storage in modern energy networks</strong></h2>

<p>Modern electricity grids increasingly have to cope with fluctuations in power generation, especially as a result of the growing share of renewables. Battery storage makes it possible to smooth out such fluctuations and provides flexibility and a reliable supply of electricity.   <strong>The main benefits of battery storage include:</strong></p>

<ul class="wp-block-list">
<li><strong>network stabilization,  </strong></li>



<li><strong>support for renewable sources  </strong></li>



<li><strong>and backup power supply.  </strong></li>
</ul>

<p>However, battery storage integration is not just a question of battery capacity, but also of proper coordination with transformers and other grid infrastructure. Only a well-designed system can optimize power flow, extend equipment life and reduce operating costs. </p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2119" height="1414" src="https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-1-1.jpg" alt="battery storage and renewables" class="wp-image-9245" srcset="https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-1-1.jpg 2119w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-1-1-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-1-1-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-1-1-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-1-1-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-1-1-2048x1367.jpg 2048w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-1-1-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-1-1-705x470.jpg 705w" sizes="auto, (max-width: 2119px) 100vw, 2119px" /></figure>

<h2 class="wp-block-heading"><br/><strong>Overview of battery storage technologies</strong></h2>

<p>There are a number of battery storage technologies that vary in capacity, durability, efficiency and cost:</p>

<ul class="wp-block-list">
<li><strong>Lithium-ion batteries are</strong> the most widely used technology in modern storage. They are used in systems where fast and efficient energy regulation is required.   </li>



<li><strong>Lead acid batteries are</strong> a traditional technology with lower costs. They are suitable for backup systems or smaller applications where high cycle frequency is not critical.   </li>



<li>Alternative technologies include <strong>sodium, vanadium and other battery types that</strong> may be more economically viable at large capacities.</li>
</ul>

<h2 class="wp-block-heading"><strong>Battery storage integration with transformers</strong></h2>

<p>Transformers play an important role in the distribution of electricity and its interconnection with storage, allowing power flow to be optimised and losses minimised. Efficient integration of battery storage with transformers is therefore crucial for reliable and energy-efficient grid operation. </p>

<ul class="wp-block-list">
<li>Battery storage needs to be sized to <strong>work with the capacity and voltage levels of the transformers.</strong> </li>



<li><strong>Modern systems allow intelligent control of the energy supply between </strong>the battery, transformer and grid according to actual demand and production.  </li>



<li><strong>Properly designed interconnection protects transformers and batteries from</strong> overloads, voltage fluctuations and other faults.</li>
</ul>

<p>The integration of battery storage represents a strategic step towards the modernisation of the energy infrastructure and provides transformer companies with a competitive advantage in implementing smart and flexible solutions.</p>

<figure class="wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex">
<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2121" height="1414" data-id="9249" src="https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-2-1.jpg" alt="battery storage" class="wp-image-9249" srcset="https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-2-1.jpg 2121w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-2-1-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-2-1-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-2-1-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-2-1-1536x1024.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-2-1-2048x1365.jpg 2048w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-2-1-1500x1000.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/08/bateriove-uloziska-2-1-705x470.jpg 705w" sizes="auto, (max-width: 2121px) 100vw, 2121px" /></figure>
</figure>

<p></p>

<h2 class="wp-block-heading"><strong>Economic aspects, price and interconnection with transformers</strong></h2>

<p>When implementing battery storage, consider not only the battery technology, but also the type of transformers the storage will work with. The cost and efficiency of the overall system will then depend on the combination of these elements. </p>

<ul class="wp-block-list">
<li><strong>Lithium-ion batteries provide</strong> high energy density and long life, making them ideal for working with <a href="https://www.bez.sk/en/dry-transformers/" target="_blank" rel="noreferrer noopener">dry-type transformers used</a> in areas with high safety requirements.</li>



<li><strong>Larger battery storage is</strong> better combined with <a href="https://www.bez.sk/en/oil-transformers/" target="_blank" rel="noreferrer noopener">oil transformers</a> that can handle higher loads and energy peaks.</li>



<li><strong>In industrial applications or</strong> critical equipment <a href="https://www.bez.sk/en/special-transformers/" target="_blank" rel="noreferrer noopener">, special transformers are used which ,</a> together with battery storage, allow the power flow to be optimised and outages to be minimised.</li>
</ul>

<p>Battery storage is an integral part of the modern energy sector, especially in an era of increasing renewable energy sources. The choice of the type of battery storage and its integration with dry oil or special transformers affects efficiency, reliability and return on investment. </p>
<p>Článok <a href="https://www.bez.sk/en/blog/battery-storage-the-future-of-energy/">Battery storage: the future of energy</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Transformation ratio: how it works and why it is important</title>
		<link>https://www.bez.sk/en/blog/transformation-ratio-how-it-works-and-why-it-is-important/</link>
		
		<dc:creator><![CDATA[Copy Digitalman]]></dc:creator>
		<pubDate>Mon, 04 Aug 2025 11:38:42 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[transformer]]></category>
		<guid isPermaLink="false">https://www.bez.sk/blog/transformation-ratio-how-it-works-and-why-it-is-important/</guid>

					<description><![CDATA[<p>In order for a transformer to effectively change the voltage between different parts of the network in electricity transmission and distribution syste...</p>
<p>Článok <a href="https://www.bez.sk/en/blog/transformation-ratio-how-it-works-and-why-it-is-important/">Transformation ratio: how it works and why it is important</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>In order for a transformer to effectively change the voltage between different parts of the network in electricity transmission and distribution systems, it must have a well-defined transformation ratio (also called transformer conversion). This is a fundamental parameter of any transformer. It determines how the voltage changes between its input and output, i.e. between the primary and secondary windings.  </strong></p>

<h2 class="wp-block-heading">Transformation ratio</h2>

<p>The transformation ratio represents <strong>the ratio between the number of turns on the primary coil and the number of turns on the secondary coil of the transformer</strong>. It determines how the electrical voltage changes as it passes through the transformer. It is denoted by the letter k <em>. In practice</em>, it is often also referred to as the ratio <strong>of input to output voltage.</strong>  </p>

<h3 class="wp-block-heading"><strong>Two basic types of transformers according to transformation ratio</strong></h3>

<p>The transformation ratio is a basic indicator of how a transformer adapts its electrical parameters to the requirements of a particular device or network:</p>

<ul class="wp-block-list">
<li><strong>Step-down transformer (k &gt; </strong> 1): it is used to reduce the voltage. An example is an adapter that converts 230 V to 12 V for household appliances. </li>



<li><strong>Step-up transformer (k &lt; </strong> 1): used to increase the voltage, for example when transferring electricity from sources to grids.</li>
</ul>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2121" height="1414" src="https://www.bez.sk/wp-content/uploads/2025/08/iStock-1420952482.jpg" alt="installation of modern transformer" class="wp-image-8749" srcset="https://www.bez.sk/wp-content/uploads/2025/08/iStock-1420952482.jpg 2121w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-1420952482-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-1420952482-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-1420952482-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-1420952482-1536x1024.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-1420952482-2048x1365.jpg 2048w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-1420952482-1500x1000.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-1420952482-705x470.jpg 705w" sizes="auto, (max-width: 2121px) 100vw, 2121px" /></figure>

<p>For decades, <strong>BEZ TRANSFORMÁTORY has been</strong> manufacturing quality transformers that accurately reflect the requirements for the correct transformation ratio from distribution networks to industrial applications.  </p>

<p>See our current offer or <a href="https://www.bez.sk/en/enquiry-form/" target="_blank" rel="noreferrer noopener">contact us for a customized transformer design.</a></p>

<h2 class="wp-block-heading"><strong>How is the transformation ratio calculated?</strong></h2>

<p>The calculation of the transformation ratio is simple. As we have already indicated, the transformation ratio is expressed either by the number of turns on the windings or by the voltages. The two expressions are mathematically equivalent: k = <strong>U₁ / U₂ = N₁ / N₂, where:</strong>  </p>

<ul class="wp-block-list">
<li>k = transformation ratio</li>



<li>U1<sub>,</sub> U2<sub>= </sub> voltages on primary and secondary windings</li>



<li>N1<sub>,</sub> N2<sub>= </sub>number of turns on primary and secondary windings</li>
</ul>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2190" height="1369" src="https://www.bez.sk/wp-content/uploads/2025/08/iStock-2076459469.jpg" alt="transformation concept, scheme" class="wp-image-8753" srcset="https://www.bez.sk/wp-content/uploads/2025/08/iStock-2076459469.jpg 2190w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-2076459469-300x188.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-2076459469-1030x644.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-2076459469-768x480.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-2076459469-1536x960.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-2076459469-2048x1280.jpg 2048w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-2076459469-1500x938.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-2076459469-705x441.jpg 705w" sizes="auto, (max-width: 2190px) 100vw, 2190px" /></figure>

<h2 class="wp-block-heading"><strong>Transformation ratio and its importance in practice</strong></h2>

<p>The correct setting of the transformation ratio has a major impact on the operation of electrical equipment and entire distribution networks:  </p>

<ul class="wp-block-list">
<li><strong>Efficient power transmission: in</strong> long-distance power <strong>transmission</strong>, voltage boosting is used with the help of transformers with a low transformation ratio. This makes it possible to reduce the current and thus the line losses. For distribution to households, the voltage is again reduced using step-down transformers.  </li>



<li><strong>Voltage adaptation for different equipment:With </strong>the right transformation ratio, we can adapt the output voltage of electrical equipment so that it operates safely and reliably.</li>



<li><strong>Measurement and protection systems:Current </strong>and voltage transformers enable high voltage currents to be monitored safely by transforming them into smaller measurable values using a precisely defined transformation ratio.</li>



<li><strong>Industrial and special applications: </strong> <a href="https://www.bez.sk/en/special-transformers/">Special transformers with atypical</a> transformation ratios are often used <strong>in industry </strong>. They allow specific voltage levels for machines, lines or laboratory instruments. This is because without the correct transformation ratio setting, these devices would not be able to function.  </li>
</ul>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2560" height="1703" src="https://www.bez.sk/wp-content/uploads/2025/08/iStock-177133659-scaled.jpg" alt="transformer failure" class="wp-image-8757" srcset="https://www.bez.sk/wp-content/uploads/2025/08/iStock-177133659-scaled.jpg 2560w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-177133659-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-177133659-1030x685.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-177133659-768x511.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-177133659-1536x1022.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-177133659-2048x1363.jpg 2048w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-177133659-1500x998.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/08/iStock-177133659-705x469.jpg 705w" sizes="auto, (max-width: 2560px) 100vw, 2560px" /></figure>

<p>The transformation ratio is therefore a key parameter of any transformer and determines how the voltage between the input and output of the device changes. Its correct understanding and calculation are essential in the design, set-up and safe operation of electrical systems. </p>

<p><strong>If you are looking for a reliable partner for the design and manufacture of customized transformers, </strong><a href="https://www.bez.sk/en/catalogues/" target="_blank" rel="noreferrer noopener"><strong>take a look at the offer of BEZ TRANSFORMÁTORY</strong></a><strong>, a leader in power solutions.</strong></p>
<p>Článok <a href="https://www.bez.sk/en/blog/transformation-ratio-how-it-works-and-why-it-is-important/">Transformation ratio: how it works and why it is important</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How the transformer works: a simple explanation for everyone</title>
		<link>https://www.bez.sk/en/blog/how-the-transformer-works-a-simple-explanation-for-everyone/</link>
		
		<dc:creator><![CDATA[Copy Digitalman]]></dc:creator>
		<pubDate>Wed, 09 Jul 2025 12:39:46 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[dry transformer]]></category>
		<category><![CDATA[oil transformer]]></category>
		<category><![CDATA[special transformers]]></category>
		<category><![CDATA[transformer]]></category>
		<category><![CDATA[transformers for renewable energy]]></category>
		<guid isPermaLink="false">https://www.bez.sk/blog/how-the-transformer-works-a-simple-explanation-for-everyone/</guid>

					<description><![CDATA[<p>Even if you don't know how a transformer works, it would be hard to imagine your life without one. Yet many people don't know what it is and how it ac...</p>
<p>Článok <a href="https://www.bez.sk/en/blog/how-the-transformer-works-a-simple-explanation-for-everyone/">How the transformer works: a simple explanation for everyone</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p><strong>Even if you don&#8217;t know how a transformer works, it would be hard to imagine your life without one. Yet many people don&#8217;t know what it is and how it actually works. That&#8217;s why today we&#8217;ll explain the principle of its operation in a simple and understandable way. We will look at the basic processes that take place in it and show you its practical use.   </strong></p>

<h2 class="wp-block-heading"><strong>The principle of operation of the transformer</strong></h2>

<p>The transformer changes the electrical voltage. It can either increase or decrease it. Its basic parts include coils of aluminum or copper wire, called <strong>primary and secondary windings.</strong> Between them is a metal core, usually made of mild steel.     </p>

<p>When an alternating electric current is applied to the first coil (primary winding), a magnetic field is created around it. This magnetic field travels through <strong>the metal core of the transformer to</strong> the second coil (secondary winding) where the changing magnetic field &#8220;touches&#8221; the conductor and causes a new electric current to appear in it. This is called <strong>induction.</strong> Depending on how many turns the second coil has compared to the first, the voltage will either increase or decrease.   </p>

<p>This phenomenon is described by <strong>Faraday&#8217;s law of electromagnetic induction,</strong> which states that &#8220;a change in <em>the magnetic field over time induces an electric voltage in the coil&#8221;.</em> This means that the transformer only works with alternating current because direct current would not create the changing magnetic field needed for induction.</p>

<p>This way the transformer changes voltage without anything moving in it. The whole process is based on a magnetic field and alternating current. </p>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2000" height="1334" src="https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-trasnsformator-2.jpg" alt="transformer" class="wp-image-8408" srcset="https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-trasnsformator-2.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-trasnsformator-2-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-trasnsformator-2-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-trasnsformator-2-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-trasnsformator-2-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-trasnsformator-2-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-trasnsformator-2-705x470.jpg 705w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /></figure>

<h2 class="wp-block-heading"><strong>How the transformer and its individual parts work</strong></h2>

<p>The transformer has two main windings. <strong>The primary winding is</strong> the part that receives the electric current from a source such as a power plant. <strong>The secondary winding passes</strong> the treated voltage to where we need to get it, for example to household appliances. The two windings are wound from copper or aluminium wires and separated from each other so that the electric current cannot flow directly, but only through the magnetic field in the core. </p>

<p><strong>The core is</strong> a metal part, most often made of steel or iron, which is placed between the windings. Its function is to conduct the magnetic field generated in the primary winding to the secondary winding. Thanks to the core, the magnetic field is concentrated and the transformer operates efficiently.  </p>

<h2 class="wp-block-heading"><strong>Types of transformers</strong></h2>

<p>In practice, we encounter various types of transformers, which differ in design and application:</p>

<ul class="wp-block-list">
<li><a href="https://www.bez.sk/en/dry-transformers/" target="_blank" rel="noreferrer noopener"><strong>Dry transformers</strong></a> have an air-cooled core and windings. They are mainly used indoors or where cleanliness and safety are important, such as in hospitals or offices. They are more environmentally friendly as they do not contain oil, but have lower maximum outputs.  </li>



<li><a href="https://www.bez.sk/en/oil-transformers/" target="_blank" rel="noreferrer noopener"><strong>Oil Transformers</strong></a> are filled with insulating oil, which helps to cool the windings and insulate them at the same time. They are mainly used in large substations and high power applications as the oil improves heat dissipation and reduces the risk of overheating.   </li>



<li>There are also <a href="https://www.bez.sk/en/special-transformers/" target="_blank" rel="noreferrer noopener"><strong>special transformers</strong></a>that are designed for specific purposes, for example, interconnecting, three-winding, inverter, single-phase, excitation or earthing transformers.  </li>



<li>Many are also adapted to work with solar panels, wind turbines or other sources. <a href="https://www.bez.sk/en/transformers-for-renewable-energy/" target="_blank" rel="noreferrer noopener"><strong>Transformers for renewable energy sources</strong></a> supply electricity with specific parameters and help to connect these sources to the grid correctly.</li>
</ul>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="2000" height="1334" src="https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-transformator-3.jpg" alt="transformer" class="wp-image-8412" srcset="https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-transformator-3.jpg 2000w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-transformator-3-300x200.jpg 300w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-transformator-3-1030x687.jpg 1030w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-transformator-3-768x512.jpg 768w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-transformator-3-1536x1025.jpg 1536w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-transformator-3-1500x1001.jpg 1500w, https://www.bez.sk/wp-content/uploads/2025/07/ako-funguje-transformator-3-705x470.jpg 705w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /></figure>

<h2 class="wp-block-heading"><strong>Practical use of transformers in electrical networks</strong></h2>

<p>Transformers safely and efficiently <strong>transmit electricity from power stations to our homes.</strong> This is because electricity is generated in large, high-voltage power stations to minimise losses in long-distance transmission. However, when it comes closer to where we want to use it, <strong>substations have to reduce</strong> its voltage to a level that is safe for homes or industry. This allows us to plug in appliances such as a TV, computer or fridge at home without worrying about anything going wrong.   </p>

<h3 class="wp-block-heading"><strong>BEZ TRANSFORMÁTORY, we could not&#8230;</strong></h3>

<p>&#8230; <strong>use common household appliances,</strong> as most of them need low voltage.</p>

<p>&#8230; <strong>to transmit electricity over long distances without</strong> huge losses.</p>

<p>&#8230; <strong>to work safely with high voltage in</strong> industry or power industry.</p>

<p>Understanding the basic principle of how a transformer works helps us to better understand how important these devices are in our daily lives. Even if we don&#8217;t see them, modern society could not function without them. </p>
<p>Článok <a href="https://www.bez.sk/en/blog/how-the-transformer-works-a-simple-explanation-for-everyone/">How the transformer works: a simple explanation for everyone</a> je zobrazený ako prvý na <a href="https://www.bez.sk/en/">BEZ Transformátory</a>.</p>